In this paper, following the research line proposed by Milankovicth (1910) and Signorini (1925), a semi-analytical approach for the analysis of masonry walls - treated as horizontally multi-layered strata of no-tension material - is proposed in order to evaluate the stress distribution generated by applied loads. The main applications concern walls subjected only to vertical loads. The goal is to identify in the masonry wall the actual bearing sub-structures by defining at each vertical and horizontal level the transversal sections generated by the unilateral behaviour. The method proposed will allow identifying the partition of the wall into macro-elements, which depend on the centre of applied loads, and wall and bricks geometrical features. The technique adopted to approach the problem can be referred to as the search for the best shape. Two cases are discussed: corbelled masonry walls surrounding windows and arch behaviour of masonry

In this paper, following the research line proposed by Signorini (1925) and previously by Milankovicth (1910), a semi-analytical approach for the analysis of masonry walls - treated as horizontally multi-layered strata of no-tension material - is proposed in order to evaluate the stress distribution generated by applied loads. The main applications concern walls subjected only to vertical loads, although it is assumed that a constitutive friction relationship is guaranteed along the horizontal joints, in the presence of horizontal actions. The goal is to identify in the masonry wall the actual bearing sub-structures by defining at each vertical and horizontal level the transversal sections generated by the unilateral behaviour. The method proposed will allow identifying the partition of the wall into macro elements, which depend on the centre of applied loads, and wall and bricks geometrical features. The technique adopted to approach the problem can be referred to as the search for the best shape. Two cases are discussed: corbelled masonry wall surrounding windows and arch behaviour of masonry over the window.

Masonry walls as orthotropic no tension structures

BASILI, Michela;
2010-01-01

Abstract

In this paper, following the research line proposed by Milankovicth (1910) and Signorini (1925), a semi-analytical approach for the analysis of masonry walls - treated as horizontally multi-layered strata of no-tension material - is proposed in order to evaluate the stress distribution generated by applied loads. The main applications concern walls subjected only to vertical loads. The goal is to identify in the masonry wall the actual bearing sub-structures by defining at each vertical and horizontal level the transversal sections generated by the unilateral behaviour. The method proposed will allow identifying the partition of the wall into macro-elements, which depend on the centre of applied loads, and wall and bricks geometrical features. The technique adopted to approach the problem can be referred to as the search for the best shape. Two cases are discussed: corbelled masonry walls surrounding windows and arch behaviour of masonry
2010
9780878492398
In this paper, following the research line proposed by Signorini (1925) and previously by Milankovicth (1910), a semi-analytical approach for the analysis of masonry walls - treated as horizontally multi-layered strata of no-tension material - is proposed in order to evaluate the stress distribution generated by applied loads. The main applications concern walls subjected only to vertical loads, although it is assumed that a constitutive friction relationship is guaranteed along the horizontal joints, in the presence of horizontal actions. The goal is to identify in the masonry wall the actual bearing sub-structures by defining at each vertical and horizontal level the transversal sections generated by the unilateral behaviour. The method proposed will allow identifying the partition of the wall into macro elements, which depend on the centre of applied loads, and wall and bricks geometrical features. The technique adopted to approach the problem can be referred to as the search for the best shape. Two cases are discussed: corbelled masonry wall surrounding windows and arch behaviour of masonry over the window.
Arch and pseudo-arch behavior
Masonry
No-tension material
Engineering (all)
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12606/4021
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
social impact