Purpose: To report variation of choroidal thickness (CT) and choroidal vascularity index (CVI) in subjects with drusen and subjects with reticular pseudodrusen (RPD) compared with healthy individuals using the Spectral-domain (SD)-Optical Coherence Tomography with enhanced depth imaging (EDI) system. Design: A prospective, observational, cross-sectional study. Subjects: Eighty-four participants. Methods: The patients were imaged using the Heidelberg Spectralis device (Heidelberg Engineering, Heidelberg, Germany) with EDI mode. EDI-OCT images were exported and then imported into image analysis ImageJ software (National Institutes of Health, Bethesda) and a semiautomated algorithm was used for subsequent quantitative analysis. Main outcome measures: This study evaluated two choroidal parameters: (i) choroidal thickness (CT); (ii) choroidal vascularity index (CVI). Results: CT analysis was performed in three different regions: (i) foveal region, (ii) parafoveal region; (iii) perifoveal region. All the analyzed regions were significantly decreased in RPD pattern, as compared with both the drusen group (p <.005) and healthy eyes (p <.005). CVI was significantly decreased in the RPD pattern, as compared with healthy eyes (p < 0.001). However, the drusenoid pattern did not have statistical significance in comparison with the control group suggesting the lower incidence of this pattern on choroidal vasculopathy. Conclusions: We report CT and CVI difference in RPD and drusen eyes. The RPD pattern seems to be a consequence of an alteration in the choroidal vascularity resulting in severe ischemia and excessive hypoxia inducing an increased risk of late AMD compared to the drusenoid pattern.

Choroidal structural changes in different intermediate AMD patterns

Porreca A.;
2021-01-01

Abstract

Purpose: To report variation of choroidal thickness (CT) and choroidal vascularity index (CVI) in subjects with drusen and subjects with reticular pseudodrusen (RPD) compared with healthy individuals using the Spectral-domain (SD)-Optical Coherence Tomography with enhanced depth imaging (EDI) system. Design: A prospective, observational, cross-sectional study. Subjects: Eighty-four participants. Methods: The patients were imaged using the Heidelberg Spectralis device (Heidelberg Engineering, Heidelberg, Germany) with EDI mode. EDI-OCT images were exported and then imported into image analysis ImageJ software (National Institutes of Health, Bethesda) and a semiautomated algorithm was used for subsequent quantitative analysis. Main outcome measures: This study evaluated two choroidal parameters: (i) choroidal thickness (CT); (ii) choroidal vascularity index (CVI). Results: CT analysis was performed in three different regions: (i) foveal region, (ii) parafoveal region; (iii) perifoveal region. All the analyzed regions were significantly decreased in RPD pattern, as compared with both the drusen group (p <.005) and healthy eyes (p <.005). CVI was significantly decreased in the RPD pattern, as compared with healthy eyes (p < 0.001). However, the drusenoid pattern did not have statistical significance in comparison with the control group suggesting the lower incidence of this pattern on choroidal vasculopathy. Conclusions: We report CT and CVI difference in RPD and drusen eyes. The RPD pattern seems to be a consequence of an alteration in the choroidal vascularity resulting in severe ischemia and excessive hypoxia inducing an increased risk of late AMD compared to the drusenoid pattern.
2021
macular and RPE dystrophies
retina - medical therapies
retinal cell biology
Retinal degenerations associated with systemic disease
retinal pathology/research
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12606/13420
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
social impact